Fire safety for short-term lets in Scotland: alarms, furniture and fire risk assessments
Fire safety is the area councils look at most closely. You need the right alarms, records that your furniture meets fire rules, and a fire risk assessment that you keep up to date.
6 minute readChecked against official sources on
In short
- Fit interlinked smoke and heat alarms: one in the living room, one in every hall and landing, and a heat alarm in the kitchen.
- Fit a carbon monoxide alarm in every room with a fixed fuel-burning appliance (other than a cooker) or a flue.
- Keep records (photos, labels or receipts) showing upholstered furniture and mattresses meet the fire safety regulations.
- Carry out a fire risk assessment, write it down and review it. For small, simple lets you can usually do this yourself.
- Leave guests a fire plan, emergency contact details and carbon monoxide alarm instructions.
Why short-term lets have extra fire duties
Holiday lets and B&B-type accommodation are not treated as private homes under fire safety law. The Fire (Scotland) Act 2005 makes the person in control of the premises (usually you) responsible for fire safety. In practice you must assess the fire risk, put suitable measures in place, keep them under review and keep good records. The Scottish Fire and Rescue Service (SFRS) enforces these duties.
Smoke and heat alarms
The licence requires "satisfactory equipment" for detecting and warning of fire. The Scottish Government's Tolerable Standard guidance defines satisfactory as:
- one smoke alarm in the room used most for daytime living (usually the living room)
- one smoke alarm in every circulation space on each storey, such as halls and landings
- one heat alarm in every kitchen
- all alarms mounted on the ceiling
- all alarms interlinked, so when one goes off they all go off. Interlinking can be wired or wireless.
Alarms can be mains-powered with a battery backup, or sealed long-life lithium battery alarms. Replaceable PP3-type batteries do not count as the main power supply. Test and maintain alarms in line with the maker's instructions.
The Scottish Government's practical fire safety guidance for small self-catering and B&B premises adds benchmarks. These include an alarm within 3 metres of each bedroom door, optical-type smoke alarms in halls and landings, and smoke alarms in every bedroom where there are more than three bedrooms. These are benchmarks to compare against, not fixed minimums. The right answer depends on your fire risk assessment.
Carbon monoxide alarms
The licence also requires equipment to warn of carbon monoxide (CO). Under the Tolerable Standard guidance:
- Fit a CO alarm in every room with a fixed combustion appliance (a boiler, fire, stove or heater burning gas, oil or solid fuel) or a flue.
- An alarm is not needed for an appliance used only for cooking, such as a gas hob.
- Use alarms meeting BS EN 50291, powered by a battery that lasts the alarm's working life, or hard-wired mains alarms.
- Place them on the ceiling at least 300 mm from walls, or high on a wall above doors and windows, and 1 to 3 metres from the appliance.
You must also leave guests instructions on what to do if the CO alarm sounds.
Furniture and mattresses
All upholstered furniture and mattresses in guest areas must comply with the Furniture and Furnishings (Fire Safety) Regulations 1988, and you must keep records that show it. The guidance suggests:
- photographs of the fire safety labels
- removing and keeping the labels themselves
- receipts that confirm compliance, for example with a product reference or accurate description
You do not need the labels to stay on the furniture, which helps because guests may remove them. If you are home sharing, this does not apply to rooms guests cannot use, such as your own bedroom.
Fire risk assessment
Annex 2 of the Scottish Government's practical fire safety guidance is written for well-managed small premises. It covers self-catering lets for up to 10 people and B&Bs in the operator's home for up to 8 guests, where:
- bedrooms lead to a traditional hall with at least one exit directly outside
- no guest accommodation is below the ground floor or above the first floor
- no storey is over 200 m² of internal floor space
If your property fits, the guidance says you should usually be able to do the assessment yourself. SFRS will not do it for you but can give advice. The steps include identifying how a fire could start, who is at risk (guests who don't know the building), how fire could spread, and what measures are needed. Then write it down and review it regularly, for example after building work.
Annex 2 benchmarks for self-catering lets include:
- a fire blanket in the kitchen
- a front door that can be opened from inside without a key
- close-fitting, solid internal doors on the escape route (gaps no more than 4 mm). Hollow doors offer poor protection.
- enough light to find the way out if the power fails
- a written plan for guests: the escape route, how to raise the alarm and how to call the fire service
If you are not confident, or your property is larger or more complex, the Scottish Government and SFRS recommend choosing an assessor from a list kept by a professional body or a UKAS-accredited certification body. SFRS publishes these on its website.
Information: Emergency lighting
The host guidance notes that emergency lighting and exit signs may be needed under the Fire Safety (Scotland) Regulations 2006 in higher-risk buildings, such as high-rise buildings, buildings with basements or rooms likely to hold more than 60 people.
What to leave for guests
- fire safety information and your fire action plan
- how to call the emergency services
- what to do if the carbon monoxide alarm sounds
Councils check fire safety in different ways. Some may visit, and each sets out what fire evidence it wants and in what format (for example whether to send a written fire risk assessment). Councils also consult the Scottish Fire and Rescue Service on applications. Check your council's page.
Failing to meet fire safety law can be a criminal offence in its own right, separate from the licence. If you are unsure about your duties, the guidance suggests getting advice.
Fire safety links closely with gas safety and electrical safety. If you'd like a checklist matched to your council, try our free requirements check.
Sources
This guide is general information based on these official sources, not legal advice. Your council’s own guidance takes priority.
- Short term lets - licensing scheme part 1: guidance for hosts and operators (2. Getting ready to apply), Scottish Government
- Short term lets - licensing scheme part 1: guidance for hosts and operators (4. How your application will be determined), Scottish Government
- Short term lets - licensing scheme part 1: guidance for hosts and operators (5. Responsibilities upon obtaining a licence), Scottish Government
- The Civic Government (Scotland) Act 1982 (Licensing of Short-term Lets) Order 2022, Schedule 3, legislation.gov.uk
- Legal requirements for short-term let accommodation, mygov.scot
- Tolerable Standard guidance: satisfactory fire detection (Chapter 16), Scottish Government
- Tolerable Standard guidance: satisfactory carbon monoxide detection (Chapter 17), Scottish Government
- Practical fire safety guidance for existing premises with sleeping accommodation (Chapter 1: Preface), Scottish Government
- Practical fire safety guidance for existing premises with sleeping accommodation (Annex 2), Scottish Government